Menu
Profile
Language

Categories

bluelab

Filters
Brand Description
See more

23

products

«1 2 3 4»

Products

Bluelab OnePen – pH, EC & Temperature Meter for Nutrient Solutions

A pH, conductivity and temperature measurement tool for nutrient solutions

This 3-in-1 Pen measures pH, conductivity (EC), and temperature, optimising nutrient uptake. Connect to the Edenic app via Bluetooth for real-time updates and comprehensive data management.

Features:

  • Replaceable, double-junction pH probe and titanium conductivity (EC) electrodes

  • Compact, ergonomic design

  • Bright, easy-to-read backlit display with simultaneous pH and conductivity (EC) readings

  • Precise readings with 0.01 pH resolution

  • Probe health indicator

  • Simple 2-point pH calibration

  • Read temperature in °C or °F

  • Measures conductivity in EC, mS/cm, CF, ppm 500 (TDS), or ppm 700

  • IP68 rated (dust and waterproof)

  • Bluelab OnePen Replacement Probe available separately

When connected to the Edenic app:

  • View measurements remotely through the app or browser

  • Real-time data and software updates

Price: 19,310.00 MKD
Quantity:

Bluelab pH 4.0 250ml - Calibration Solution

Features:

  • Contains 250 / 500 ml
  • Boost your pH products’ longevity with regular cleaning and calibration

Calibration of Bluelab products is the process of adjusting your pH or EC meters and pens using specific EC or pH meter calibration solutions. This process aligns the instrument’s readings with known reference values, ensuring measurement accuracy.

Calibration is recommended once a month, or more frequently if the instrument is used heavily, for continuous monitoring or used with organic soils or nutrients. Many Bluelab products provide an on-screen calibration indicator to help you stay on schedule. After successful calibration, a confirmation check mark appears on the display. This check mark remains visible for 30 days, after which it disappears to indicate that recalibration is required.

Extend the lifespan and performance of your Bluelab equipment through correct care, regular calibration, and routine maintenance. Proper handling ensures your tools continue to deliver accurate, dependable measurements throughout their working life.

Price: 750.00 MKD

BlueLab Conductivity probe care

Probe cleaning is one of the most important parts of owning or operating anyBluelab meter, monitor or controller.

If the probe is contaminated or dirty, it affects the accuracy of the reading displayed. The Bluelab Truncheon® Meter and Bluelab Conductivity Probes read low when the probe is contaminated.

The probe surface is where the instrument takes the reading of the solution. The information is sent back from the probe to the electronic brain of the instrument. A calculation is then done in the instruments brain or micro-computer and a reading is then displayed. If the information sent back from the probe is inaccurate due to probe surface contamination then the reading will be inaccurate.

Cleaning the conductivity probe is a very easy task and prolongs the life of your probe.

  • Cleaninginstructionsinside box lid
  • 500ml 2.77 EC Conductivity Standard Solution
  • Decanter vessel
  • Bluelab Conductivity Probe Cleaner
  • Bluelab Chamois(probe cleaning instrument)
Price: 1,310.00 MKD
Quantity:

Bluelab pH 7.0 250ml - Calibration Solution

Features:

  • Contains 250 / 500 ml
  • Boost your pH products’ longevity with regular cleaning and calibration

Calibration of Bluelab products is the process of adjusting your pH or EC meters and pens using specific EC or pH meter calibration solutions. This process aligns the instrument’s readings with known reference values, ensuring measurement accuracy.

Calibration is recommended once a month, or more frequently if the instrument is used heavily, for continuous monitoring or used with organic soils or nutrients. Many Bluelab products provide an on-screen calibration indicator to help you stay on schedule. After successful calibration, a confirmation check mark appears on the display. This check mark remains visible for 30 days, after which it disappears to indicate that recalibration is required.

Extend the lifespan and performance of your Bluelab equipment through correct care, regular calibration, and routine maintenance. Proper handling ensures your tools continue to deliver accurate, dependable measurements throughout their working life.

Price: 750.00 MKD

Bluelab pH Controller WiFi

Bluelab pH Controller WiFi – 24/7 pH control of your tank, anywhere, anytime from your phone.

  • Built-in Wi-Fi (can be disabled). View and control from your mobile device; visit Edenic.io for more information.

  • Safety blocks prevent overdosing.

  • Automatic resumption of dosing after power loss.

  • Precise pH dosing using the built-in Bluelab peristaltic pump.

  • Controls pH up (alkaline) or down (acidic).

  • High/low alarms alert you when parameters are out of range.

  • Dosing routine ensures efficient mixing before the next dose.

  • Cable length: 2 m / 6 ft for optimal positioning and viewing.

  • Built-in variable-speed pump (max. 120 ml/min / 4.06 fl oz).

Price: 53,450.00 MKD
Quantity:

Bluelab pH Calibration and Cleaning Kit

Probe cleaning and correctly storing pH probes ensures you get the most accurate readings possible and will maximize the life of a probe.
 
The probe surface is where the instrument takes the reading of the solution or soil/media. If the probe face is dirty or contaminated, the readings may be inaccurate. Much like the windshield of a car, if it’s dirty you can’t see out! If the probe face is dirty, it cannot read the solution or soil accurately.

Price: 2,590.00 MKD
Quantity:
Page 1 of 4